dc.description.abstractThis paper presents the results of tests on the vibration of a normal triangular tube bundle subjected to air–water cross-flow. The pitch-to-diameter ratio of the bundle is 1.5, and the tube diameter is 38 mm. The tubes were preferentially flexible in one direction. Both the lift and the drag direction were tested. A wide range of void fractions and fluid velocities was tested. Fluidelastic instabilities and tube resonances were observed. The resonances induced significant vibration amplitudes at high void fractions in the lift direction. The results are compared with those obtained with a rotated triangular tube bundle. They show that the normal triangular configuration is more stable than the rotated triangular configuration.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleFluidelastic Instability in a Normal Triangular Tube Bundle Subjected to Air-Water Cross-Flow
dc.typeJournal Paper
dc.journal.volume133
dc.journal.issue6
dc.journal.titleJournal of Pressure Vessel Technology
dc.identifier.doi10.1115/1.4004562
dc.journal.fristpage61301
dc.identifier.eissn1528-8978
dc.keywordsFlow (Dynamics)
dc.keywordsFluids
dc.keywordsDrag (Fluid dynamics)
dc.keywordsVibration
dc.keywordsPorosity
dc.keywordsWater
dc.keywordsCross-flow AND Force
dc.treeJournal of Pressure Vessel Technology:;2011:;volume( 133 ):;issue: 006