• Login
    View Item 
    •   DSpace Home
    • ASME
    • Journal of Nanotechnology in Engineering and Medicine
    • View Item
    •   DSpace Home
    • ASME
    • Journal of Nanotechnology in Engineering and Medicine
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    A Multivariate Logistical Model for Identifying the Compressive Sensitivity of Single Rat Tactile Receptors as Nanobiosensors

    Thumbnail
    View/Open
    JNEMAA-28051#011002_1.pdf (688.5Kb)
    Date
    2011
    Author
    Sean S. Kohles
    Sam Bradshaw
    Shelley S. Mason
    Fred J. Looft
    Metadata
    Show full item record
    Abstract
    Tactile sensation is a complex manifestation of mechanical stimuli applied to the skin. At the most fundamental level of the somatosensory system is the cutaneous mechanoreceptor. The objective here was to establish a framework for modeling afferent mechanoreceptor behavior as a nanoscale biosensor under dynamic compressive loads using multivariate regression techniques. A multivariate logistical model was chosen because the system contains continuous input variables and a singular binary-output variable corresponding to the nerve action potential. Subsequently, this method was used to quantify the sensitivity of ten rapidly adapting afferents from rat hairy skin due to the stimulus metrics of compressive stress, strain, their respective time derivatives, and interactions. In vitro experiments involving compressive stimulation of isolated afferents using pseudorandom and nonrepeating noise sequences were completed. An analysis of the data was performed using multivariate logistical regression producing odds ratios (ORs) as a metric associated with mechanotransduction. It was determined that cutaneous mechanoreceptors are preferentially sensitive to stress (mean ORmax=26.10), stress rate (mean ORmax=15.03), strain (mean ORmax=12.01), and strain rate (mean ORmax=7.29) typically occurring within 7.3 ms of the nerve response. As a novel approach to receptor characterization, this analytical framework was validated for the multiple-input, binary-output neural system.
    URI
    http://yetl.yabesh.ir/yetl/handle/yetl/147329
    Collections
    • Journal of Nanotechnology in Engineering and Medicine

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV