Show simple item record

dc.contributor.authorIgor V. Shevchuk
dc.contributor.authorMartin Schnieder
dc.contributor.authorSean C. Jenkins
dc.contributor.authorBernhard Weigand
dc.contributor.authorJens von Wolfersdorf
dc.contributor.authorSven Olaf Neumann
dc.date.accessioned2017-05-09T00:45:03Z
dc.date.available2017-05-09T00:45:03Z
dc.date.copyrightMay, 2011
dc.date.issued2011
dc.identifier.issn0022-1481
dc.identifier.otherJHTRAO-27912#051701_1.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/146702
dc.description.abstractNumerical results for an internal ribbed cooling channel including a 180 deg bend with a 2:1 inlet and a 1:1 aspect ratio outlet channel were validated against experimental results in terms of spatially resolved heat transfer distributions, pressure losses, and velocity distributions. The numerical domain consisted of one rib segment in the inlet channel and three ribs segments in the outlet channel to reduce the overall numerical effort and allow for an extensive parametric study. The results showed good agreement for both heat transfer magnitudes and spatial distributions, and the numerical results captured the predominate flow physics resulting from the 180 deg bend. The production of Dean vortices and acceleration of the flow in the bend produced strongly increased heat transfer on both the ribbed and unribbed walls in the outlet channel in addition to increases due to the ribs. Numerical simulations were performed for a wide range of divider wall-to-tip wall distances, which influenced the position of the highest heat transfer levels on the outlet walls and changed the shape of the heat transfer distribution on the tip wall. Analysis of section averages of heat transfer in the bend and outlet channel showed a strong influence of the tip wall distance, while no effect was seen upstream of the bend. A similarly large effect on pressure losses in the bend was observed with varying tip wall position. Trends in averaged heat transfer varied linearly with tip wall distance, while pressure losses followed a nonlinear trend, resulting in an optimum tip wall distance with respect to heat transfer efficiency.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleValidation and Analysis of Numerical Results for a Varying Aspect Ratio Two-Pass Internal Cooling Channel
dc.typeJournal Paper
dc.journal.volume133
dc.journal.issue5
dc.journal.titleJournal of Heat Transfer
dc.identifier.doi10.1115/1.4003080
dc.journal.fristpage51701
dc.identifier.eissn1528-8943
dc.keywordsHeat transfer
dc.keywordsChannels (Hydraulic engineering)
dc.keywordsFlow (Dynamics) AND Engineering simulation
dc.treeJournal of Heat Transfer:;2011:;volume( 133 ):;issue: 005
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record