Show simple item record

dc.contributor.authorSaptarshi Basu
dc.contributor.authorGregory J. Michna
dc.contributor.authorYoav Peles
dc.contributor.authorMichael K. Jensen
dc.contributor.authorSidy Ndao
dc.date.accessioned2017-05-09T00:45:03Z
dc.date.available2017-05-09T00:45:03Z
dc.date.copyrightMay, 2011
dc.date.issued2011
dc.identifier.issn0022-1481
dc.identifier.otherJHTRAO-27912#051503_1.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/146699
dc.description.abstractA detailed experimental study was carried out on the critical heat flux (CHF) condition for flow boiling of R134a in single circular microtubes. The test sections had inner diameters (ID) of 0.50 mm, 0.96 mm, and 1.60 mm. Experiments were conducted over a large range of mass flux, inlet subcooling, saturation pressure, and vapor quality. CHF occurred under saturated conditions at high qualities and increased with increasing mass fluxes, tube diameters, and inlet subcoolings. CHF generally, but not always, decreases with increasing saturation pressures and vapor qualities. The experimental data were mapped to the flow pattern maps developed by [2005, “Two-Phase Flow Regime Transitions in Microchannels: A Comparative Experimental Study,” Nanoscale Microscale Thermophys. Eng., 9, pp. 165–182] and and [2007, “A New Type of Diabatic Flow Pattern Map for Boiling Heat Transfer in Microchannels,” J. Micromech. Microeng., 17, pp. 788–796]. Based on these maps, CHF mainly occurred in the annular flow regime in the larger tubes. The flow pattern for the 0.50 mm ID tube was not conclusively identified. Four correlations—the Bowring correlation, the Katto-Ohno correlation, the Thome correlation, and the Zhang correlation—were used to predict the experimental data. The correlations predicted the correct experimental trend, but the mean absolute error (MAE) was high (>15%) A new correlation was developed to fit the experimental data with a MAE of 10%.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleFlow Boiling of R134a in Circular Microtubes—Part II: Study of Critical Heat Flux Condition
dc.typeJournal Paper
dc.journal.volume133
dc.journal.issue5
dc.journal.titleJournal of Heat Transfer
dc.identifier.doi10.1115/1.4003160
dc.journal.fristpage51503
dc.identifier.eissn1528-8943
dc.keywordsFlow (Dynamics)
dc.keywordsBoiling
dc.keywordsCritical heat flux AND Subcooling
dc.treeJournal of Heat Transfer:;2011:;volume( 133 ):;issue: 005
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record