Show simple item record

dc.contributor.authorGongnan Xie
dc.contributor.authorBengt Sundén
dc.contributor.authorWeihong Zhang
dc.date.accessioned2017-05-09T00:45:01Z
dc.date.available2017-05-09T00:45:01Z
dc.date.copyrightJune, 2011
dc.date.issued2011
dc.identifier.issn0022-1481
dc.identifier.otherJHTRAO-27915#061902_1.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/146679
dc.description.abstractThe blade tip region encounters high thermal loads because of the hot gas leakage flows, and it must therefore be cooled to ensure a long durability and safe operation. A common way to cool a blade tip is to design serpentine passages with a 180 deg turns under the blade tip-cap inside the turbine blade. Improved internal convective cooling is therefore required to increase blade tip lifetime. Pins, dimples, and protrusions are well recognized as effective devices to augment heat transfer in various applications. In this paper, enhanced heat transfer of an internal blade tip-wall has been predicted numerically. The computational models consist of a two-pass channel with 180 deg turn and arrays of circular pins, hemispherical dimples, or protrusions internally mounted on the tip-wall. Inlet Reynolds numbers are ranging from 100,000 to 600,000. The overall performance of the two-pass channels is evaluated. Numerical results show that the heat transfer enhancement of the pinned-tip is up to a factor of 3.0 higher than that of a smooth tip while the dimpled-tip and protruded-tip provide about 2.0 times higher heat transfer. These augmentations are achieved at the cost of an increase of pressure drop by less than 10%. By comparing the present cooling concepts with pins, dimples, and protrusions, it is shown that the pinned-tip exhibits best performance to improve the blade tip cooling. However, when disregarding the added active area and considering the added mechanical stress, it is suggested that the usage of dimples is more suitable to enhance blade tip cooling, especially at low Reynolds numbers.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleComparisons of Pins/Dimples/Protrusions Cooling Concepts for a Turbine Blade Tip-Wall at High Reynolds Numbers
dc.typeJournal Paper
dc.journal.volume133
dc.journal.issue6
dc.journal.titleJournal of Heat Transfer
dc.identifier.doi10.1115/1.4003558
dc.journal.fristpage61902
dc.identifier.eissn1528-8943
dc.keywordsHeat transfer
dc.keywordsCooling
dc.keywordsChannels (Hydraulic engineering)
dc.keywordsReynolds number
dc.keywordsTurbine blades
dc.keywordsPins (Engineering)
dc.keywordsTurbulence
dc.keywordsBlades
dc.keywordsTemperature AND Pressure drop
dc.treeJournal of Heat Transfer:;2011:;volume( 133 ):;issue: 006
dc.contenttypeFulltext