Show simple item record

dc.contributor.authorMohamed S. El-Genk
dc.contributor.authorAmir F. Ali
dc.date.accessioned2017-05-09T00:44:57Z
dc.date.available2017-05-09T00:44:57Z
dc.date.copyrightAugust, 2011
dc.date.issued2011
dc.identifier.issn0022-1481
dc.identifier.otherJHTRAO-27919#081503_1.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/146635
dc.description.abstractPresented are the results of experiments that investigated nucleate boiling of PF-5060 on microporous Cu surface layers at saturation and 10 K, 20 K, and 30 K subcooling. The three microporous layers, electrochemically deposited on 10×10 mm2 Cu substrates and investigated herein, are ∼139 μm, 171 μm, and 220 μm thick. The critical heat flux increases linearly with increased subcooling, ΔTsub, at an average rate of 4.5%/K. For the 171 μm thick, Cu microporous surface, saturation boiling CHF of 27.8 W/cm2 increases to 63.25 W/cm2 at ΔTsub=30 K, while the saturation hMNB of 13.5 W/cm2 K decreases slightly to 12.7 W/cm2 K at ΔTsub=30 K. The values of the surface superheat, ΔTsat, at hMNB and CHF increase from 2.0 K and 2.16 K at saturation to 4.2 and 6.42 K at 30 K subcooling.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleSubcooled Boiling of PF-5060 Dielectric Liquid on Microporous Surfaces
dc.typeJournal Paper
dc.journal.volume133
dc.journal.issue8
dc.journal.titleJournal of Heat Transfer
dc.identifier.doi10.1115/1.4003748
dc.journal.fristpage81503
dc.identifier.eissn1528-8943
dc.keywordsBoiling
dc.keywordsDielectric liquids
dc.keywordsSubcooling
dc.keywordsNucleate boiling
dc.keywordsCritical heat flux
dc.keywordsTemperature AND Heat transfer coefficients
dc.treeJournal of Heat Transfer:;2011:;volume( 133 ):;issue: 008
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record