Show simple item record

dc.contributor.authorLizhan Bai
dc.contributor.authorG. P. Peterson
dc.contributor.authorDongsheng Wen
dc.contributor.authorGuiping Lin
dc.date.accessioned2017-05-09T00:44:45Z
dc.date.available2017-05-09T00:44:45Z
dc.date.copyrightDecember, 2011
dc.date.issued2011
dc.identifier.issn0022-1481
dc.identifier.otherJHTRAO-27928#121501_1.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/146530
dc.description.abstractSupercritical startup of cryogenic loop heat pipes (CLHPs) has been investigated both analytically and experimentally. Mathematical model of the supercritical startup has been established using the nodal network method, and parametric study is conducted where the effects of working fluid charged pressure, parasitic heat load from the ambient, etc., on the supercritical startup characteristics are incorporated and evaluated. The result improves understanding of the effects of these parameters on supercritical startup and identification of those conditions under which supercritical startup can and will occur. In addition, the modeling effort has led to an enhanced understanding of supercritical startup performance.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleModeling and Analysis of Supercritical Startup of a Cryogenic Loop Heat Pipe
dc.typeJournal Paper
dc.journal.volume133
dc.journal.issue12
dc.journal.titleJournal of Heat Transfer
dc.identifier.doi10.1115/1.4004595
dc.journal.fristpage121501
dc.identifier.eissn1528-8943
dc.keywordsHeat
dc.keywordsFluids
dc.keywordsStress
dc.keywordsModeling
dc.keywordsTemperature
dc.keywordsVapors
dc.keywordsNetworks
dc.keywordsHeat pipes
dc.keywordsPressure AND Cooling
dc.treeJournal of Heat Transfer:;2011:;volume( 133 ):;issue: 012
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record