Show simple item record

dc.contributor.authorV. Lawlor
dc.contributor.authorC. Hochenauer
dc.contributor.authorD. Meissner
dc.contributor.authorA. G. Olabi
dc.contributor.authorK. Klein
dc.contributor.authorS. Cordiner
dc.contributor.authorA. Mariani
dc.contributor.authorS. Kuehn
dc.contributor.authorS. Griesser
dc.contributor.authorG. Zauner
dc.contributor.authorG. Buchinger
dc.date.accessioned2017-05-09T00:44:32Z
dc.date.available2017-05-09T00:44:32Z
dc.date.copyrightDecember, 2011
dc.date.issued2011
dc.identifier.issn2381-6872
dc.identifier.otherJFCSAU-28951#061019_1.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/146425
dc.description.abstractMicro-tubular solid oxide fuel cells (MT-SOFCs) are a much smaller version of larger tubular SOFCs. They are operational within seconds and allow a higher power density per volume than the larger version. Hence they are a potential technology for automotive, auxiliary and small scale power supply devices. In this study a commercially available computational fluid dynamic (CFD) software program was used to predict a MT-SOFCs performance when located inside a high temperature wind tunnel experimental apparatus. In Part I, experimentally measured temperature profiles were recorded via thermo-graphic analyses and I/V curves. These measurements were used in this study to establish the predictability and validity of the CFD code and furthermore understand the MT-SOFC attributes measured in Part I. A maximum 4% I/V curve deviation and 6 K temperature deviation between the experimentally measured and model predicted results was observed. Thus, the model predicted the MT-SOFCs performance in the experimental environment very accurately. A very critical observation was the current density and temperature profile across the MT-SOFC that was strongly dependent on the distance from the hydrogen/fuel inlet. Not only was the model validated but also a grid and quantitative solution analysis is explicitly shown and discussed. This resulted in the optimum grid density and the indication that a normally undesirable high grid aspect ratio is acceptable for similar MT-SOFC modeling. These initial simulations and grid/solution analysis are the prerequisite before performing a further study including multiple MT-SOFCs within a stack using different fuels is also envisaged.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleThe Use of a High Temperature Wind Tunnel for MT-SOFC Testing—Part II: Use of Computational Fluid Dynamics Software in Order to Study Previous Measurements
dc.typeJournal Paper
dc.journal.volume8
dc.journal.issue6
dc.journal.titleJournal of Fuel Cell Science and Technology
dc.identifier.doi10.1115/1.4004507
dc.journal.fristpage61019
dc.identifier.eissn2381-6910
dc.keywordsComputational fluid dynamics
dc.keywordsSolid oxide fuel cells
dc.keywordsTemperature
dc.keywordsWind tunnels
dc.keywordsComputer software
dc.keywordsFuels
dc.keywordsCurrent density AND High temperature
dc.treeJournal of Fuel Cell Science and Technology:;2011:;volume( 008 ):;issue: 006
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record