Show simple item record

dc.contributor.authorMichele Margarone
dc.contributor.authorGiuseppe Gorla
dc.contributor.authorGianluca Valenti
dc.contributor.authorMatteo C. Romano
dc.contributor.authorStefano Biffi
dc.contributor.authorStefano Magi
dc.contributor.authorPaolo Siboni
dc.contributor.authorAntonio Giuffrida
dc.contributor.authorEmanuele Negri
dc.contributor.authorEnnio Macchi
dc.date.accessioned2017-05-09T00:43:19Z
dc.date.available2017-05-09T00:43:19Z
dc.date.copyrightMarch, 2011
dc.date.issued2011
dc.identifier.issn0195-0738
dc.identifier.otherJERTD2-26574#012001_1.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/145863
dc.description.abstractSurface oil and gas treatment facilities in service for decades are likely to be oversized due to the natural depletion of their reservoirs. Despite these plants might have been designed modularly, meaning they comprise multiple identical units serving the same task, such units operate often in conditions far from the design. This work analyzes the revamping options of an existing upstream gas facility, chosen because representative of a wide set of plants. It presents a flexible process simulation model, implemented in the HYSYS environment and dynamically linked to an Excel spreadsheet, which includes the performance maps of all turbomachineries and the main characteristics of the investigated modifications. The model may be used to run simulations for various gas input conditions and to predict the performance over 1 year of operation and for different possible future scenarios. The first objective is to assess economically the considered options, which shall be applied only if yielding short return times of the investment since the reservoir is mature. Moreover, all options are appreciated adopting a figure of merit, here defined, that compares the overall energy consumption to the one calculated with state-of-the-art technologies. In addition, exergy and environmental analyses are executed.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleRevamping, Energy Efficiency, and Exergy Analysis of an Existing Upstream Gas Treatment Facility
dc.typeJournal Paper
dc.journal.volume133
dc.journal.issue1
dc.journal.titleJournal of Energy Resources Technology
dc.identifier.doi10.1115/1.4003627
dc.journal.fristpage12001
dc.identifier.eissn1528-8994
dc.keywordsElectric motors
dc.keywordsGaseous fuels
dc.keywordsCompressors
dc.keywordsHeat recovery
dc.keywordsIncinerators
dc.keywordsEnergy efficiency
dc.keywordsExergy
dc.keywordsProcess simulation
dc.keywordsTurbines
dc.keywordsExergy analysis
dc.keywordsIndustrial plants
dc.keywordsFlow (Dynamics)
dc.keywordsPressure
dc.keywordsDesign
dc.keywordsPlant layout
dc.keywordsCycles
dc.keywordsGas turbines
dc.keywordsCompression
dc.keywordsWater
dc.keywordsSteam AND Reservoirs
dc.treeJournal of Energy Resources Technology:;2011:;volume( 133 ):;issue: 001
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record