    A Novel Approach to Evaluation of Vibration Source Separation Based on Spatial Distribution of Sensors and Fourier Transforms

    Thumbnail
    View/Open
    JDSMAA-26565#061022_1.pdf (2.003Mb)
    Date
    2011
    Author
    Ali Mahvash
    Aouni A. Lakis
    Metadata
    Show full item record
    Abstract
    An obstacle in diagnosis of multicomponent machinery using multiple sensors to acquire vibration data is firstly found in the data acquisition itself. This is due to the fact that vibration signals collected by each sensor are a mixture of vibration produced by different components and noise; it is not evident what signals are produced by each component. A number of research studies have been carried out in which this problem was considered a blind source separation (BSS) problem and different mathematical methods were used to separate the signals. One complexity with applying such mathematical methods to separate vibration sources is that no metric or standard measure exists to evaluate the quality of the separation. In this study, a method based on statistical energy analysis (SEA) is proposed using Fourier transforms and the spatial distance between sensors and components. The principle of this method is based on the fact that each sensor, with respect to its location in the system, collects a different version of the vibration produced in the system. By applying a short time Fourier transform to the signals collected by multiple sensors and making use of a priori knowledge of the spatial distribution of sensor locations with respect to the components, the source of the peaks on the frequency spectra of the signals can be identified and attributed to the components. The performance of the method was verified using a series of experimental tests on synthetic signals and real laboratory signals collected from different bearings and the results confirmed the efficacy of the method.
    URI
    http://yetl.yabesh.ir/yetl/handle/yetl/145659
    Collections
    • Journal of Dynamic Systems, Measurement, and Control

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV