    Measurement of the Heat Capacity of Copper Thin Films Using a Micropulse Calorimeter

    Thumbnail
    View/Open
    JHTRAO-27878#012403_1.pdf (530.2Kb)
    Date
    2010
    Author
    Jun Yu
    Zhen’an Tang
    Fengtian Zhang
    Haitao Ding
    Zhengxing Huang
    Metadata
    Show full item record
    Abstract
    This paper presents a micropulse calorimeter for heat capacity measurement of thin films. Optimization of the structure and data processing methods of the microcalorimeter improved the thermal isolation and temperature uniformity and reduced the heat capacity measurement errors. Heat capacities of copper thin films with thicknesses from 20 nm to 340 nm are measured in the temperature range from 300 K to 420 K in vacuum of 1 mPa. The specific heat of the 340 nm Cu film is close to the literature data of bulk Cu. For the thinner films, the data shows that the specific heat increases with the decreasing of film thickness (or the average crystalline size).
    URI
    http://yetl.yabesh.ir/yetl/handle/yetl/143955
    Collections
    • Journal of Heat Transfer

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV