Show simple item record

dc.contributor.authorYoon Jo Kim
dc.contributor.authorYoung-Joon Lee
dc.contributor.authorSung-Kyu Lim
dc.contributor.authorYogendra K. Joshi
dc.contributor.authorAndrei G. Fedorov
dc.date.accessioned2017-05-09T00:39:01Z
dc.date.available2017-05-09T00:39:01Z
dc.date.copyrightApril, 2010
dc.date.issued2010
dc.identifier.issn0022-1481
dc.identifier.otherJHTRAO-27885#041009_1.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/143889
dc.description.abstractIt is now widely recognized that the three-dimensional (3D) system integration is a key enabling technology to achieve the performance needs of future microprocessor integrated circuits (ICs). To provide modular thermal management in 3D-stacked ICs, the interlayer microfluidic cooling scheme is adopted and analyzed in this study focusing on a single cooling layer performance. The effects of cooling mode (single-phase versus phase-change) and stack/layer geometry on thermal management performance are quantitatively analyzed, and implications on the through-silicon-via scaling and electrical interconnect congestion are discussed. Also, the thermal and hydraulic performance of several two-phase refrigerants is discussed in comparison with single-phase cooling. The results show that the large internal pressure and the pumping pressure drop are significant limiting factors, along with significant mass flow rate maldistribution due to the presence of hot-spots. Nevertheless, two-phase cooling using R123 and R245ca refrigerants yields superior performance to single-phase cooling for the hot-spot fluxes approaching ∼300 W/cm2. In general, a hybrid cooling scheme with a dedicated approach to the hot-spot thermal management should greatly improve the two-phase cooling system performance and reliability by enabling a cooling-load-matched thermal design and by suppressing the mass flow rate maldistribution within the cooling layer.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleThermal Characterization of Interlayer Microfluidic Cooling of Three-Dimensional Integrated Circuits With Nonuniform Heat Flux
dc.typeJournal Paper
dc.journal.volume132
dc.journal.issue4
dc.journal.titleJournal of Heat Transfer
dc.identifier.doi10.1115/1.4000885
dc.journal.fristpage41009
dc.identifier.eissn1528-8943
dc.keywordsFlow (Dynamics)
dc.keywordsCooling
dc.keywordsChannels (Hydraulic engineering)
dc.keywordsMicrofluidics
dc.keywordsHeat flux
dc.keywordsPressure drop
dc.keywordsIntegrated circuits
dc.keywordsGeometry
dc.keywordsFluids AND Thermal management
dc.treeJournal of Heat Transfer:;2010:;volume( 132 ):;issue: 004
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record