Show simple item record

dc.contributor.authorPatrick T. Garrity
dc.contributor.authorJames F. Klausner
dc.contributor.authorRenwei Mei
dc.date.accessioned2017-05-09T00:38:43Z
dc.date.available2017-05-09T00:38:43Z
dc.date.copyrightDecember, 2010
dc.date.issued2010
dc.identifier.issn0022-1481
dc.identifier.otherJHTRAO-27902#121901_1.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/143715
dc.description.abstractThe air side heat transfer performance of three aluminum foam samples and three modified carbon foam samples are examined for comparison with multilouvered fins often found in compact heat exchangers. The aluminum foam samples have a bulk density of 216 kg/m3 with pore sizes of 0.5, 1, and 2 mm. The modified carbon foam samples have bulk densities of 284, 317, and 400 kg/m3 and machined flow passages of 3.2 mm in diameter. The samples were placed in a forced convection arrangement using a foil heater as the heat source and ambient air as the sink. A constant heat flux of 9.77 kW/m2 is applied throughout the experiments with the mean air velocity ranging from 1 to 6 m/s as the control parameter. The steady volume-averaged momentum equation and a two-equation nonequilibrium heat transfer model are employed to extract the volumetric heat transfer coefficients. Pressure drop measurements are correlated with the Darcy–Forcheimer relation. Empirical heat transfer correlations for the aluminum and carbon foam samples are provided. Using a hypothetical heat exchanger considering only the thermal resistance between the ambient air and the outer tube wall, the air side performance for each sample is modeled based on the local heat transfer coefficients and friction factors obtained from experiments. The performance of each sample is evaluated based on a coefficient of performance (COP, defined as the ratio of the total heat removed to the electrical input of the blower), compactness factor (CF, defined as the total heat removed per unit volume), and power density (PD, defined as the total heat removed per unit mass). Results show the carbon foam samples provide significant improvement in CF but the COP and PD are considerably lower than that for comparable multilouvered fin heat exchangers.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titlePerformance of Aluminum and Carbon Foams for Air Side Heat Transfer Augmentation
dc.typeJournal Paper
dc.journal.volume132
dc.journal.issue12
dc.journal.titleJournal of Heat Transfer
dc.identifier.doi10.1115/1.4002172
dc.journal.fristpage121901
dc.identifier.eissn1528-8943
dc.keywordsFlow (Dynamics)
dc.keywordsHeat transfer
dc.keywordsFoams (Chemistry)
dc.keywordsAluminum
dc.keywordsCarbon
dc.keywordsHeat exchangers
dc.keywordsPressure drop
dc.keywordsHeat transfer coefficients
dc.keywordsHeat
dc.keywordsFins
dc.keywordsEquations
dc.keywordsDensity
dc.keywordsFluids AND Carbon fibers
dc.treeJournal of Heat Transfer:;2010:;volume( 132 ):;issue: 012
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record