• Login
    View Item 
    •   DSpace Home
    • ASME
    • Journal of Dynamic Systems, Measurement, and Control
    • View Item
    •   DSpace Home
    • ASME
    • Journal of Dynamic Systems, Measurement, and Control
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Efficient Operation of Air-Side Economizer Using Extremum Seeking Control

    Thumbnail
    View/Open
    JDSMAA-26520#031009_1.pdf (1.176Mb)
    Date
    2010
    Author
    Pengfei Li
    John E. Seem
    Yaoyu Li
    Metadata
    Show full item record
    Abstract
    As the heating, ventilating, and air conditioning (HVAC) systems accounts for a major sector of energy consumption for commercial buildings, there has been a greater demand for improving the efficiency of such systems. The air-side economizers have been developed as a class of energy-saving HVAC devices that may increase the energy efficiency by taking advantage of outdoor air during cool or cold weather. However, many economizers do not operate in the expected manner and waste even more energy than before installation, mostly due to the unreliable sensors and actuators in practice. Better control strategy is needed for optimal and robust operation. In this paper, an extremum-seeking control (ESC) based self-optimizing strategy is proposed to minimize the energy consumption, with the feedback of chilled water supply command rather than the temperature and humidity measurements. The mechanical cooling load is minimized by seeking the optimal outdoor air damper opening in real time. Such scheme does not need temperature and humidity sensors, and depends much less on the knowledge of the economizer model. Simulation was performed on a MODELICA based transient model of a single-duct air-handling unit developed with DYMOLA and AIRCONDITIONING LIBRARY . The simulation results demonstrated the potential of using ESC to achieve the minimal mechanical cooling load in a self-optimizing manner. In addition, an antiwindup ESC scheme is proposed to handle the ESC windup issue due to actuator (damper) saturation. The simulation results validated the effectiveness of the proposed antiwindup ESC.
    URI
    http://yetl.yabesh.ir/yetl/handle/yetl/142874
    Collections
    • Journal of Dynamic Systems, Measurement, and Control

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV