dc.description.abstractThis paper presents the results of a test series to study the vibration behavior of a normal triangular tube bundle subjected to two-phase Freon cross flow. A normal triangular tube bundle of pitch over diameter ratio of 1.5 was tested over a broad range of void fractions and mass fluxes. Fluidelastic instabilities, random turbulence excitation, and damping were investigated. The results were compared with those obtained for a similar tube bundle tested in an air-water cross flow and to those for a rotated triangular bundle similarly tested in Freon.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleVibration of a Normal Triangular Tube Bundle Subjected to Two-Phase Freon Cross Flow
dc.typeJournal Paper
dc.journal.volume131
dc.journal.issue5
dc.journal.titleJournal of Pressure Vessel Technology
dc.identifier.doi10.1115/1.3147985
dc.journal.fristpage51302
dc.identifier.eissn1528-8978
dc.treeJournal of Pressure Vessel Technology:;2009:;volume( 131 ):;issue: 005