Show simple item record

dc.contributor.authorJ. Bons
dc.contributor.authorDaniel Fletcher
dc.contributor.authorBrad Borchert
dc.date.accessioned2017-05-09T00:33:57Z
dc.date.available2017-05-09T00:33:57Z
dc.date.copyrightJanuary, 2009
dc.date.issued2009
dc.identifier.issn0022-1481
dc.identifier.otherJHTRAO-27853#011302_1.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/141137
dc.description.abstractThe effect of lateral conduction on convective heat transfer measurements using a transient infrared technique over an isolated spherical roughness element (bump) is evaluated. Comparisons are made between a full 3D finite-volume analysis and a simpler 1D transient conduction model. The surface temperature history was measured with a high resolution infrared camera during an impulsively started hot-gas flow at a flow Reynolds number of 860,000. The boundary layer was turbulent with the bump heights equivalent to 0.75, 1.5, and 3 times the boundary layer momentum thickness. When considering transient conduction effects only in the bump wake, the 1D approximate method underestimates the actual Stanton number estimated with the 3D model. This discrepancy is only 10% for a 75% change in St number occurring over a surface distance of 10 mm (the half-width of the wake). When the actual bump topology is accounted for in estimating the Stanton number on the bump itself with the 3D analysis technique, the increased surface area of the finite-volume cells on the protruding bump actually decreases the predicted value of St locally. The net result is that the two effects can cancel each other, and in some cases the 1D approximate technique can provide a reasonably accurate estimate of the surface heat transfer without the added complexity of the 3D finite-volume method. For the case of the largest bump tested, with maximum surface angularity exceeding 60 deg, the correction for 3D topology yields a 1D St estimate that is within 20–30% of the 3D estimate over much of the bump surface. These observed effects are valid for transient measurement techniques while the opposite is true for steady-state measurement techniques.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleTransient Method for Convective Heat Transfer Measurement With Lateral Conduction—Part II: Application to an Isolated Spherical Roughness Element
dc.typeJournal Paper
dc.journal.volume131
dc.journal.issue1
dc.journal.titleJournal of Heat Transfer
dc.identifier.doi10.1115/1.2976785
dc.journal.fristpage11302
dc.identifier.eissn1528-8943
dc.keywordsFlow (Dynamics)
dc.keywordsTemperature
dc.keywordsHeat transfer
dc.keywordsHeat conduction
dc.keywordsSurface roughness
dc.keywordsWakes
dc.keywordsConvection
dc.keywordsBoundary layers
dc.keywordsTemperature gradients AND Steady state
dc.treeJournal of Heat Transfer:;2009:;volume( 131 ):;issue: 001
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record