Show simple item record

dc.contributor.authorRandeep Singh
dc.contributor.authorMasataka Mochizuki
dc.contributor.authorAliakbar Akbarzadeh
dc.date.accessioned2017-05-09T00:33:42Z
dc.date.available2017-05-09T00:33:42Z
dc.date.copyrightAugust, 2009
dc.date.issued2009
dc.identifier.issn0022-1481
dc.identifier.otherJHTRAO-27867#082601_1.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/141015
dc.description.abstractTwo phase heat transfer devices based on the miniature version of loop heat pipe (LHP) can provide very promising cooling solutions for the compact electronic devices due to their high heat flux management capability and long distance heat transfer with minimal temperature losses. This paper discusses the effect of the wick properties on the heat transfer characteristics of the miniature LHP. The miniature model of the LHP with disk-shaped evaporator, 10 mm thick and 30 mm disk diameter, was designed using copper containment vessel and water as the working fluid, which is the most acceptable combination in electronic cooling applications. In the investigation, wick structures with different physical properties including thermal conductivity, pore radius, porosity, and permeability and with different structural topology including monoporous or biporous evaporating face were used. It was experimentally observed that copper wicks are able to provide superior thermal performance than nickel wicks, particularly for low to moderate heat loads due to their low heat conducting resistance. With monoporous copper wick, maximum evaporator heat transfer coefficient (hev) of 26,270 W/m2 K and evaporator thermal resistance (Rev) of 0.06–0.10°C/W were achieved. For monoporous nickel wick, the corresponding values were 20,700 W/m2 K for hev and 0.08–0.21°C/W for Rev. Capillary structure with smaller pore size, high porosity, and high permeability showed better heat transfer characteristics due to sufficient capillary pumping capability, low heat leaks from evaporator to compensation chamber and larger surface area to volume ratio for heat exchange. In addition to this, biporous copper wick structure showed much higher heat transfer coefficient of 83,787 W/m2 K than monoporous copper wick due to improved evaporative heat transfer at wick wall interface and separated liquid and vapor flow pores. The present work was able to classify the importance of the wick properties in the improvement of the thermal characteristics for miniature loop heat pipes.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleEffect of Wick Characteristics on the Thermal Performance of the Miniature Loop Heat Pipe
dc.typeJournal Paper
dc.journal.volume131
dc.journal.issue8
dc.journal.titleJournal of Heat Transfer
dc.identifier.doi10.1115/1.3109994
dc.journal.fristpage82601
dc.identifier.eissn1528-8943
dc.keywordsPressure
dc.keywordsFlow (Dynamics)
dc.keywordsHeat
dc.keywordsTemperature
dc.keywordsHeat transfer
dc.keywordsFluids
dc.keywordsVapors
dc.keywordsPermeability
dc.keywordsCopper
dc.keywordsNickel
dc.keywordsStress
dc.keywordsThermal conductivity
dc.keywordsEvaporation
dc.keywordsHeat pipes
dc.keywordsPorosity
dc.keywordsThermal resistance
dc.keywordsHeat transfer coefficients
dc.keywordsLeakage
dc.keywordsWater
dc.keywordsComputer cooling
dc.keywordsEngineering prototypes AND Cooling
dc.treeJournal of Heat Transfer:;2009:;volume( 131 ):;issue: 008
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record