Show simple item record

dc.contributor.authorDavid A. Dillard
dc.contributor.authorMichael W. Ellis
dc.contributor.authorYeh-Hung Lai
dc.contributor.authorMichael K. Budinski
dc.contributor.authorYongqiang Li
dc.contributor.authorJacob R. Grohs
dc.contributor.authorCraig S. Gittleman
dc.contributor.authorScott W. Case
dc.date.accessioned2017-05-09T00:33:24Z
dc.date.available2017-05-09T00:33:24Z
dc.date.copyrightAugust, 2009
dc.date.issued2009
dc.identifier.issn2381-6872
dc.identifier.otherJFCSAU-28938#031014_1.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/140842
dc.description.abstractThe use of pressurized blister specimens to characterize the biaxial strength and durability of proton exchange membranes (PEMs) is proposed, simulating the biaxial stress states that are induced within constrained membranes of operating PEM fuel cells. PEM fuel cell stacks consist of layered structures containing the catalyzed PEMs that are surrounded by gas diffusion media and clamped between bipolar plates. The surfaces of the bipolar plates are typically grooved with flow channels to facilitate distribution of the reactant gases and water by-product. The channels are often on the order of a few millimeters across, leaving the sandwiched layers tightly constrained by the remaining lands of the bipolar plates, preventing in-plane strains. The hydrophilic PEMs expand and contract significantly as the internal humidity, and to a lesser extent, temperature varies during fuel cell operation. These dimensional changes induce a significant biaxial stress state within the confined membranes that are believed to contribute to pinhole formation and membrane failure. Pressurized blister tests offer a number of advantages for evaluating the biaxial strength to bursting or to detectable leaking. Results are presented for samples of three commercial membranes that were tested at 80°C and subjected to a pressure that was ramped to burst. The bursting pressures exhibit significant time dependence that is consistent with failure of viscoelastic materials. Rupture stresses, estimated with the classic Hencky’s solution for pressurized membranes in conjunction with a quasielastic estimation, are shown to be quite consistent for a range of blister diameters tested. The technique shows considerable promise not only for measuring biaxial burst strength but also for measuring constitutive properties, creep to rupture, and cyclic fatigue damage. Because the tests are easily amenable to leak detection, pressurized blister tests offer the potential for characterizing localized damage events that would not be detectable in more commonly used uniaxial strength tests. As such, this specimen configuration is expected to become a useful tool in characterizing mechanical integrity of proton exchange membranes.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleOn the Use of Pressure-Loaded Blister Tests to Characterize the Strength and Durability of Proton Exchange Membranes
dc.typeJournal Paper
dc.journal.volume6
dc.journal.issue3
dc.journal.titleJournal of Fuel Cell Science and Technology
dc.identifier.doi10.1115/1.3007431
dc.journal.fristpage31014
dc.identifier.eissn2381-6910
dc.keywordsPressure
dc.keywordsStress
dc.keywordsDurability
dc.keywordsMembranes
dc.keywordsRupture
dc.keywordsProton exchange membranes
dc.keywordsFailure
dc.keywordsTemperature
dc.keywordsFuel cells
dc.keywordsLeakage AND Creep
dc.treeJournal of Fuel Cell Science and Technology:;2009:;volume( 006 ):;issue: 003
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record