dc.description.abstractThis paper presents the experimental testing of relatively cost-effective expanders in an organic Rankine cycle (ORC) to produce power from low-grade energy. Gerotor and scroll expanders were the two types of expanders tested to determine their applicability in producing power from low-grade energy. The results of the experimental testing showed that both types of expanders were good candidates to be used in an ORC. The gerotor and scroll expanders tested produced 2.07 kW and 2.96 kW, and had isentropic efficiencies of 0.85 and 0.83, respectively. Also the paper presents results of an analytical model produced that predicted improved cycle efficiency with certain changes. One change was the flow rate of the working fluid in the cycle was properly matched with the inlet pocket volume and rotational speed of the expander. Also, the volumetric expansion ratio of the expander was matched to the specific volume ratio of the working fluid (R-123) across the expander. The model incorporated the efficiencies of the expanders and pump obtained during experimental testing, and combined two expanders in series to match the specific volume ratio of the working fluid. The model determined the power produced by the expanders, and subtracted the power required by the working fluid pump and the condenser fan. From that, the model calculated the net power produced to be 6271 W and the overall energy efficiency of the cycle to be 7.7%. When the ORC was simulated to be integrated with the exhaust of a stationary engine, the exergetic efficiency, exergy destroyed, and reduction in diesel fuel while still producing the same amount of power during 2500 h of operation were 22.1%, 22,169 W, and 4,012 L (1060 U.S. gal), respectively. Consequently, the model presents a very realistic design based on results from experimental testing to cost-effectively use low-grade energy.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleExperimental Testing of Gerotor and Scroll Expanders Used in, and Energetic and Exergetic Modeling of, an Organic Rankine Cycle
dc.typeJournal Paper
dc.journal.volume131
dc.journal.issue1
dc.journal.titleJournal of Energy Resources Technology
dc.identifier.doi10.1115/1.3066345
dc.journal.fristpage12201
dc.identifier.eissn1528-8994
dc.keywordsFlow (Dynamics)
dc.keywordsTemperature
dc.keywordsFluids
dc.keywordsEngines
dc.keywordsExergy
dc.keywordsBoilers
dc.keywordsHeat exchangers
dc.keywordsModeling
dc.keywordsPumps
dc.keywordsTesting
dc.keywordsCondensers (steam plant)
dc.keywordsCycles
dc.keywordsExhaust systems
dc.keywordsRankine cycle
dc.keywordsPressure AND Water
dc.treeJournal of Energy Resources Technology:;2009:;volume( 131 ):;issue: 001
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record