dc.contributor.authorK. N. Shukla
dc.date.accessioned2017-05-09T00:32:20Z
dc.date.available2017-05-09T00:32:20Z
dc.date.copyrightJune, 2009
dc.date.issued2009
dc.identifier.issn1528-9044
dc.identifier.otherJEPAE4-26295#024502_1.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/140316
dc.description.abstractAn analytical expression for the heat transport capability of micro heat pipe is derived. The vapor continuum limitation has been considered in deriving the heat transport capability of a micro heat pipe. As the micro heat pipe uses sharp-cornered square, triangular, or other polygonal channels that can serve as capillary arteries, its transport capability depends on the capillary limit. It has been shown that the operating limit of the micro heat pipe depends on the vapor continuum limitation, capillary limit, and the gravity.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleHeat Transfer Limitation of a Micro Heat Pipe
dc.typeJournal Paper
dc.journal.volume131
dc.journal.issue2
dc.journal.titleJournal of Electronic Packaging
dc.identifier.doi10.1115/1.3103970
dc.journal.fristpage24502
dc.identifier.eissn1043-7398
dc.keywordsHeat
dc.keywordsHeat transfer
dc.keywordsHeat pipes
dc.keywordsVapors
dc.keywordsGravity (Force)
dc.keywordsChannels (Hydraulic engineering) AND Equations
dc.treeJournal of Electronic Packaging:;2009:;volume( 131 ):;issue: 002