    A Novel Projection Moiré System for Measuring PWBA Warpage Using Simulated Optimized Convective Reflow Process

    Thumbnail
    View/Open
    JEPAE4-26295#021006_1.pdf (785.1Kb)
    Date
    2009
    Author
    Reinhard E. Powell
    I. Charles Ume
    Metadata
    Show full item record
    Abstract
    The shadow moiré technique is a widely used method of measuring printed wiring board (PWB) warpage. It has a high resolution, high accuracy, and is suitable for use in an online environment. The shortcoming of the shadow moiré technique is that it cannot be used to measure PWBs populated with chip packages. In this paper, a novel warpage measurement system based on the projection moiré technique is presented. The system can be used to measure bare PWBs, as well as PWBs populated with chip packages. In order to use the projection moiré system to accurately determine the warpage of PWBs and chip packages separately, an automated chip package detection algorithm based on active contours is utilized. Unlike the shadow moiré technique, which uses a glass grating, the projection moiré technique uses a virtual grating. The virtual grating sizes can be adjusted, making it versatile for measuring various PWB and chip package sizes. Without the glass grating, which is a substantial heat inertia, the PWB/printed wiring board assembly (PWBA) sample can be heated more evenly during the thermal process. The projection moiré system described in this paper can also be used to measure the warpage of PWBs/PWBAs/chip packages during convective reflow processes. In this paper, the characteristics of the projection moiré warpage measurement system will be described. In addition, the system will be used to measure the warpage of a PWB and plastic ball grid array packages during a Lee optimized convective reflow process (, 2002, Reflow Soldering Processes and Troubleshooting SMT, BGA, CSP, and Flip Chip Technologies, Butterworth-Heinemann, MA). It is concluded that this projection moiré warpage measurement system is a powerful tool to study the warpage of populated PWBs during convective reflow processes.
    URI
    http://yetl.yabesh.ir/yetl/handle/yetl/140305
    Collections
    • Journal of Electronic Packaging

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV