Show simple item record

dc.contributor.authorSk. Faruque Ali
dc.contributor.authorAnanth Ramaswamy
dc.date.accessioned2017-05-09T00:32:13Z
dc.date.available2017-05-09T00:32:13Z
dc.date.copyrightMarch, 2009
dc.date.issued2009
dc.identifier.issn0022-0434
dc.identifier.otherJDSMAA-26489#021009_1.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/140235
dc.description.abstractMagnetorheological dampers are intrinsically nonlinear devices, which make the modeling and design of a suitable control algorithm an interesting and challenging task. To evaluate the potential of magnetorheological (MR) dampers in control applications and to take full advantages of its unique features, a mathematical model to accurately reproduce its dynamic behavior has to be developed and then a proper control strategy has to be taken that is implementable and can fully utilize their capabilities as a semi-active control device. The present paper focuses on both the aspects. First, the paper reports the testing of a magnetorheological damper with an universal testing machine, for a set of frequency, amplitude, and current. A modified Bouc–Wen model considering the amplitude and input current dependence of the damper parameters has been proposed. It has been shown that the damper response can be satisfactorily predicted with this model. Second, a backstepping based nonlinear current monitoring of magnetorheological dampers for semi-active control of structures under earthquakes has been developed. It provides a stable nonlinear magnetorheological damper current monitoring directly based on system feedback such that current change in magnetorheological damper is gradual. Unlike other MR damper control techniques available in literature, the main advantage of the proposed technique lies in its current input prediction directly based on system feedback and smooth update of input current. Furthermore, while developing the proposed semi-active algorithm, the dynamics of the supplied and commanded current to the damper has been considered. The efficiency of the proposed technique has been shown taking a base isolated three story building under a set of seismic excitation. Comparison with widely used clipped-optimal strategy has also been shown.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleTesting and Modeling of MR Damper and Its Application to SDOF Systems Using Integral Backstepping Technique
dc.typeJournal Paper
dc.journal.volume131
dc.journal.issue2
dc.journal.titleJournal of Dynamic Systems, Measurement, and Control
dc.identifier.doi10.1115/1.3072154
dc.journal.fristpage21009
dc.identifier.eissn1528-9028
dc.keywordsDampers
dc.keywordsTesting
dc.keywordsForce AND Modeling
dc.treeJournal of Dynamic Systems, Measurement, and Control:;2009:;volume( 131 ):;issue: 002
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record