Show simple item record

dc.contributor.authorC.-J. Kuo
dc.contributor.authorY. Peles
dc.date.accessioned2017-05-09T00:29:02Z
dc.date.available2017-05-09T00:29:02Z
dc.date.copyrightJuly, 2008
dc.date.issued2008
dc.identifier.issn0022-1481
dc.identifier.otherJHTRAO-27839#072403_1.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/138529
dc.description.abstractCritical heat flux conditions for water at subatmospheric pressures in an array of silicon-based, 227μm hydraulic diameter, rectangular microchannels were experimentally studied. Experiments were conducted at exit pressures from 0.1atmto1atm, mass fluxes from 86kg∕m2sto303kg∕m2s, and an effective heat flux up to 444W∕cm2. The annular flow pattern revealed during flow visualization and the high exit qualities at CHF conditions suggest dryout to be the CHF mechanism. An analysis, based on the experimental results and known CHF characteristics, on the dependency of the critical heat flux on various variables was performed. It was found that the boiling number at the CHF condition was approximately a constant.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleCritical Heat Flux of Water at Subatmospheric Pressures in Microchannels
dc.typeJournal Paper
dc.journal.volume130
dc.journal.issue7
dc.journal.titleJournal of Heat Transfer
dc.identifier.doi10.1115/1.2909077
dc.journal.fristpage72403
dc.identifier.eissn1528-8943
dc.keywordsFlow (Dynamics)
dc.keywordsWater
dc.keywordsMicrochannels
dc.keywordsCritical heat flux
dc.keywordsBoiling AND Heat flux
dc.treeJournal of Heat Transfer:;2008:;volume( 130 ):;issue: 007
dc.contenttypeFulltext