Show simple item record

dc.contributor.authorAshis K. Mazumder
dc.contributor.authorSujoy K. Saha
dc.date.accessioned2017-05-09T00:28:59Z
dc.date.available2017-05-09T00:28:59Z
dc.date.copyrightAugust, 2008
dc.date.issued2008
dc.identifier.issn0022-1481
dc.identifier.otherJHTRAO-27841#081702_1.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/138498
dc.description.abstractThe thermohydraulic performance of turbulent flow of air through rectangular and square ribbed ducts with twisted-tape inserts has been experimentally studied. The performance is influenced by the twisted-tape-generated swirl flow and the boundary layer separation, reattachment, and flow recirculation due to the ribs. Correlations developed for friction factor and Nusselt number satisfactorily predict the experimental data. The performance of the ribbed ducts with full-length twisted-tape inserts is found to be better than only ribbed ducts and ducts with only twisted-tape inserts. The regularly spaced twisted-tape elements in specific cases significantly perform better than their full-length counterparts. However, the short-length twisted-tape performance is worse than the full-length twisted tapes.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleEnhancement of Thermohydraulic Performance of Turbulent Flow in Rectangular and Square Ribbed Ducts With Twisted-Tape Inserts
dc.typeJournal Paper
dc.journal.volume130
dc.journal.issue8
dc.journal.titleJournal of Heat Transfer
dc.identifier.doi10.1115/1.2909611
dc.journal.fristpage81702
dc.identifier.eissn1528-8943
dc.keywordsFriction
dc.keywordsTurbulence
dc.keywordsDucts
dc.keywordsFlow (Dynamics)
dc.keywordsHeat transfer
dc.keywordsPressure drop AND Reynolds number
dc.treeJournal of Heat Transfer:;2008:;volume( 130 ):;issue: 008
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record