Show simple item record

dc.contributor.authorV. A. C. Haanappel
dc.contributor.authorM. Bertoldi
dc.contributor.authorT. Zandonella
dc.contributor.authorJ. Mertens
dc.contributor.authorJ. Remmel
dc.contributor.authorL. G. J. de Haart
dc.date.accessioned2017-05-09T00:28:44Z
dc.date.available2017-05-09T00:28:44Z
dc.date.copyrightFebruary, 2008
dc.date.issued2008
dc.identifier.issn2381-6872
dc.identifier.otherJFCSAU-28932#011004_1.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/138373
dc.description.abstractForschungszentrum Juelich (FZJ) has developed over the past years a well-known SOFC stack technology for a planar cell configuration. 1.5mm thick anode supported large-area cells based on a NiO∕YSZ (anode) and a YSZ (electrolyte) system are integrated in a stack using bipolar plates made of a special ferritic stainless steel acting as current collector and gas distributor. Materials, processes, and surface treatments have been selected and optimized to reduce mismatch between different components and to achieve high power densities. The recent SOFC stacks of F-design, fuelled with humidified hydrogen and air has demonstrated a power density as high as 0.6W∕cm2 at 800°C and a stable behavior up to 8000h of operation. These tests are usually performed in standard conditions, using a low value of fuel utilization and a precise control of gas composition, fuel, and airflow rates and temperature distribution. It seems quite difficult to maintain the same strict control of these parameters when the stack operates in an actual device. Therefore, it is of interest to investigate the effect of different experimental conditions on the electrochemical performance that can simulate stack behavior as integrated in a real system. For example, an actual fuel cell system is designed to operate with fuel utilization in the range between 70% and 85% due to efficiency considerations. In addition, variations of the electric load and of the corresponding flow rates must be expected that give rise to temperature changes and gradients within the stack. Part of these effects might be detrimental for the stack service life, and can be limited by a well-designed balance of plant of the system. In this contribution, results of a series of tests on a 4-cells SOFC stack of F design, manufactured by FZJ and conducted in a new SOFC test bench by Eurocoating, are presented. This facility allows the investigation of the performance of stacks up to 1kW as a function of several experimental parameters, including the amplitude of compressive loading, inlet gas temperature and pressure, flow rate, and fuel utilization.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleDemonstration of a 4-Cells SOFC Stack Under Different Experimental Conditions
dc.typeJournal Paper
dc.journal.volume5
dc.journal.issue1
dc.journal.titleJournal of Fuel Cell Science and Technology
dc.identifier.doi10.1115/1.2398952
dc.journal.fristpage11004
dc.identifier.eissn2381-6910
dc.keywordsFlow (Dynamics)
dc.keywordsTemperature
dc.keywordsElectric potential
dc.keywordsAnodes
dc.keywordsFuels
dc.keywordsDensity
dc.keywordsSolid oxide fuel cells
dc.keywordsHydrogen
dc.keywordsDesign
dc.keywordsAir flow
dc.keywordsCurrent density
dc.keywordsTesting
dc.keywordsPressure
dc.keywordsFuel cells
dc.keywordsElectrolytes AND Stainless steel
dc.treeJournal of Fuel Cell Science and Technology:;2008:;volume( 005 ):;issue: 001
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record