dc.description.abstractWe have investigated the behavior of an operating polymer electrolyte fuel cell (PEFC) with supplying a mixture of carbon monoxide (CO) and hydrogen (H2) gases into the anode to develop the PEFC diagnosis method for anode CO poisoning by reformed hydrogen fuel. We analyze the characteristics of the CO poisoned anode of the PEFC at 80°C including CO adsorption and electro-oxidation behaviors by current-voltage (I‐V) measurement and electrochemical impedance spectroscopy (EIS) to find parameters useful for the diagnosis. I‐V curves show the dependence of the output voltage on the CO adsorption and electro-oxidation. EIS analyses are performed with an equivalent circuit model consisting of several resistances and capacitances attributed to the activation, diffusion, and adsorption∕desorption processes. As the result, those resistances and capacitances are shown to change with current density and anode overpotential depending on the CO adsorption and electro-oxidation. The characteristic changes of those parameters show that they can be used for the diagnosis of the CO poisoning.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleElectrochemical Impedance Parameters for the Diagnosis of a Polymer Electrolyte Fuel Cell Poisoned by Carbon Monoxide in Reformed Hydrogen Fuel
dc.typeJournal Paper
dc.journal.volume5
dc.journal.issue4
dc.journal.titleJournal of Fuel Cell Science and Technology
dc.identifier.doi10.1115/1.2931462
dc.journal.fristpage41013
dc.identifier.eissn2381-6910
dc.keywordsImpedance (Electricity)
dc.keywordsOvervoltage
dc.keywordsCarbon
dc.keywordsAnodes
dc.keywordsFuel cells
dc.keywordsPolymers
dc.keywordsCurrent density
dc.keywordsElectrolytes
dc.keywordsoxidation
dc.keywordsPatient diagnosis
dc.keywordsHydrogen fuels
dc.keywordsElectric potential
dc.keywordsMixtures
dc.keywordsHydrogen
dc.keywordsElectrodes
dc.keywordsCapacitance AND Circuits
dc.treeJournal of Fuel Cell Science and Technology:;2008:;volume( 005 ):;issue: 004
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record