dc.description.abstractAn experiment was performed to study air∕water slug frequency in a horizontal clear pipe by means of visual inspection and differential pressure measurement in the range of 0–1∕s. Results showed that a simplified model for slug pressure drop allowed the differential pressure data to compare favorably with visual observations for slug frequency. It was concluded that this technique gives a proper estimation of slug frequency, given only basic flow information. It is recommended that this technique be used when constrained to differential pressure or used to analyze existing differential pressure data.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleA Simple Technique for Determining Slug Frequency Using Differential Pressure
dc.typeJournal Paper
dc.journal.volume130
dc.journal.issue1
dc.journal.titleJournal of Energy Resources Technology
dc.identifier.doi10.1115/1.2824297
dc.journal.fristpage14501
dc.identifier.eissn1528-8994
dc.keywordsPressure
dc.keywordsSlug
dc.keywordsFlow (Dynamics)
dc.keywordsPressure drop AND Pipes
dc.treeJournal of Energy Resources Technology:;2008:;volume( 130 ):;issue: 001