    Limit Loads of Pressure Components Using the Reference Two-Bar Structure

    Thumbnail
    View/Open
    JPVTAS-28481#280_1.pdf (372.7Kb)
    Date
    2007
    Author
    R. Seshadri
    R. Adibi-Asl
    Metadata
    Show full item record
    Abstract
    Limit loads for mechanical components and structures are determined in this paper by invoking the concept of equivalence of “static indeterminacy,” which relates a multidimensional pressure component configuration to a “reference two-bar structure.” Simple scaling relationships are developed that enable the rapid determination of limit loads. The reference two-bar structure method is applied to a number of pressure component configurations with or without notches.