Show simple item record

dc.contributor.authorMiranda N. Shaw
dc.contributor.authorVijay K. Goel
dc.contributor.authorKoichi Sairyo
dc.contributor.authorJayant Jangra
dc.contributor.authorAshok Biyani
dc.contributor.authorNabil Ebraheim
dc.date.accessioned2017-05-09T00:25:18Z
dc.date.available2017-05-09T00:25:18Z
dc.date.copyrightJune, 2007
dc.date.issued2007
dc.identifier.issn1932-6181
dc.identifier.otherJMDOA4-27984#176_1.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/136588
dc.description.abstractAn experimentally validated three-dimensional (3D) finite element (FE) model of the ligamentous L3–S1 segment was used to study the effects of artificial facet designs on the segment biomechanics (motion, facet loads, and stresses). The intact model was modified to simulate several artificial facet designs across the L4–L5 segment including capping with and without screws and pedicle screw based designs with sliding articulating surfaces. For the pedicle screw based design, the effect of increasing the connecting shaft thickness and increasing width surrounding the pedicle screw, butted against the vertebral pedicle for further support, was studied. All of the FE models were evaluated in response to 6 Nm moment in extension, flexion, bending, and rotation. The predicted increases in motion, compared to the intact case, were smaller. The predicted facet loads decreased up to 25.7% in extension and 25.1% in bending at the implanted level as compared to intact spine segment. For all of the loading modes, the stresses in both implant designs were less than the yield stress of titanium. Therefore, the implants are unlikely to fail. Additional cadaver and other experimental protocols are essential for the evaluations of the most appropriate designs identified through the FE investigations.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleApplication of the Finite Element Technique in the Design and Evaluation of the Artificial Facets for the Lumbar Spine
dc.typeJournal Paper
dc.journal.volume1
dc.journal.issue2
dc.journal.titleJournal of Medical Devices
dc.identifier.doi10.1115/1.2735974
dc.journal.fristpage176
dc.journal.lastpage179
dc.identifier.eissn1932-619X
dc.keywordsStress
dc.keywordsDesign
dc.keywordsFinite element analysis
dc.keywordsFinite element model
dc.keywordsLumbar spine
dc.keywordsSpinal pedicle screws
dc.keywordsMotion
dc.keywordsRotation
dc.keywordsScrews
dc.keywordsThickness
dc.keywordsTitanium AND Biomechanics
dc.treeJournal of Medical Devices:;2007:;volume( 001 ):;issue: 002
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record