• Login
    View Item 
    •   DSpace Home
    • ASME
    • Journal of Heat Transfer
    • View Item
    •   DSpace Home
    • ASME
    • Journal of Heat Transfer
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Novel Design of a Miniature Loop Heat Pipe Evaporator for Electronic Cooling

    Thumbnail
    View/Open
    JHTRAO-27825#1445_1.pdf (318.1Kb)
    Date
    2007
    Author
    Randeep Singh
    Masataka Mochizuki
    Aliakbar Akbarzadeh
    Chris Dixon
    Metadata
    Show full item record
    Abstract
    Miniature loop heat pipes (mLHPs) are coming up with a promising solution for the thermal management of futuristic electronics systems. In order to implement these devices inside compact electronics, their evaporator has to be developed with small thickness while preserving the unique thermal characteristics and physical concept of the loop scheme. This paper specifically addresses the design and testing of a mLHP with a flat evaporator only 5mm thick for the cooling of high performance microprocessors for electronic devices. A novel concept was used to achieve very small thickness for the mLHP evaporator in which the compensation chamber was positioned on the sides of the wick structure and incorporated in the same plane as the evaporator. This is unlike the conventional design of the flat evaporator for mLHP in which the compensation chamber, as a rule, adds to the overall thickness of the evaporator. The loop was made from copper with water as the heat transfer fluid. For capillary pumping of the working fluid around the loop, a sintered nickel wick with 3–5μm pore radius and 75% porosity was used. In the horizontal orientation, the device was able to transfer heat fluxes of 50W∕cm2 at a distance of up to 150mm by using a transport line with 2mm internal diameter. In the range of applied power, the evaporator was able to achieve steady state without any temperature overshoots or symptoms of capillary structure dryouts. For the evaporator and condenser at the same level and under forced air cooling, the minimum value of 0.62°C∕W for mLHP thermal resistance from evaporator to condenser (Rec) was achieved at a maximum heat load of 50W with the corresponding junction temperature of 98.5°C. The total thermal resistance (Rt) of the mLHP was within 1.5–5.23°C∕W. At low heat loads, the mLHP showed some thermal and hydraulic oscillations in the transport lines, which were predominately due to the flow instabilities imposed by parasitic heat leaks to the compensation chamber. It is concluded form the outcomes of the present investigation that the proposed design of the mLHP evaporator can be effectively used for the thermal control of the compact electronic devices with high heat flux capabilities.
    URI
    http://yetl.yabesh.ir/yetl/handle/yetl/136205
    Collections
    • Journal of Heat Transfer

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV