Show simple item record

dc.contributor.authorShin’ya Obara
dc.date.accessioned2017-05-09T00:24:24Z
dc.date.available2017-05-09T00:24:24Z
dc.date.copyrightAugust, 2007
dc.date.issued2007
dc.identifier.issn2381-6872
dc.identifier.otherJFCSAU-28930#238_1.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/136104
dc.description.abstractThe capacity reduction of a solid-polymer-membrane-type fuel cell (PEFC) with a reformer by load leveling and by improving the efficiency of part-load operation of the reformer is considered. The power generation efficiency of a fuel cell improves by supplying gas with a high oxygen concentration to the cathode. During periods of low electricity demand, the fuel cell is operated using reformed gas and air, and water electrolysis operation is also performed. When the electric power load is large, gases stored in cylinders are supplied to the fuel cell for operation. Using the proposed method, high efficiency operation and a reduction in the fuel cell capacity are possible.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleLoad Leveling of Fuel Cell System by Oxygen Concentration Control of Cathode Gas
dc.typeJournal Paper
dc.journal.volume4
dc.journal.issue3
dc.journal.titleJournal of Fuel Cell Science and Technology
dc.identifier.doi10.1115/1.2743068
dc.journal.fristpage238
dc.journal.lastpage247
dc.identifier.eissn2381-6910
dc.keywordsStress
dc.keywordsFuel cells
dc.keywordsOxygen
dc.keywordsWater
dc.keywordsElectrolysis
dc.keywordsElectricity (Physics) AND Hydrogen
dc.treeJournal of Fuel Cell Science and Technology:;2007:;volume( 004 ):;issue: 003