Show simple item record

dc.contributor.authorTeemu Vesanen
dc.contributor.authorKrzysztof Klobut
dc.contributor.authorJari Shemeikka
dc.date.accessioned2017-05-09T00:24:22Z
dc.date.available2017-05-09T00:24:22Z
dc.date.copyrightNovember, 2007
dc.date.issued2007
dc.identifier.issn2381-6872
dc.identifier.otherJFCSAU-28931#511_1.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/136078
dc.description.abstractDue to constantly increasing electricity consumption, networks are becoming overloaded and unstable. Decentralization of power generation using small-scale local cogeneration plants becomes an interesting option to improve economy and energy reliability of buildings in terms of both electricity and heat. It is expected that stationary applications in buildings will be one of the most important fields for fuel cell systems. In northern countries, like Finland, efficient utilization of heat from fuel cells is feasible. Even though the development of some fuel cell systems has already progressed to a field trial stage, relatively little is known about the interaction of fuel cells with building energy systems during a dynamic operation. This issue could be addressed using simulation techniques, but there has been a lack of adequate simulation models. International cooperation under IEA/ECBCS/Annex 42 aims at filling this gap, and the study presented in this paper is part of this effort. Our objective was to provide the means for studying the interaction between a building and a fuel cell system by incorporating a realistic fuel cell model into a building energy simulation. A two-part model for a solid-oxide fuel cell system has been developed. One part is a simplified model of the fuel cell itself. The other part is a system level model, in which a control volume boundary is assumed around a fuel cell power module and the interior of it is regarded as a “black box.” The system level model has been developed based on a specification defined within Annex 42. The cell model (programed in a spreadsheet) provides a link between inputs and outputs of the black box in the system model. This approach allows easy modifications whenever needed. The system level model has been incorporated into the building simulation tool IDA-ICE (Indoor Climate and Energy) using the neutral model format language. The first phase of model implementation has been completed. In the next phase, model validation will continue. The final goal is to create a comprehensive but flexible model, which could serve as a reliable tool to simulate the operation of different fuel cell systems in different buildings.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleImplementation of a Fuel Cell System Model Into Building Energy Simulation Software IDA-ICE
dc.typeJournal Paper
dc.journal.volume4
dc.journal.issue4
dc.journal.titleJournal of Fuel Cell Science and Technology
dc.identifier.doi10.1115/1.2759510
dc.journal.fristpage511
dc.journal.lastpage515
dc.identifier.eissn2381-6910
dc.keywordsSimulation
dc.keywordsFuel cells
dc.keywordsIce
dc.keywordsComputer software
dc.keywordsFuels
dc.keywordsHeat AND Combined heat and power
dc.treeJournal of Fuel Cell Science and Technology:;2007:;volume( 004 ):;issue: 004
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record