dc.description.abstractA temperature response factors model of vertical thermal energy extraction boreholes is presented to evaluate electricity generation from underground coal fires and waste banks. Sensitivity and life-cycle cost analyses are conducted to assess the impact of system parameters on the production of 1 MW of electrical power using a theoretical binary-cycle power plant. Sensitivity analyses indicate that the average underground temperature has the greatest impact on the exiting fluid temperatures from the ground followed by fluid flow rate and ground thermal conductivity. System simulations show that a binary-cycle power plant may be economically feasible at ground temperatures as low as 190°C.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleEvaluation of Electricity Generation From Underground Coal Fires and Waste Banks
dc.typeJournal Paper
dc.journal.volume129
dc.journal.issue2
dc.journal.titleJournal of Energy Resources Technology
dc.identifier.doi10.1115/1.2718576
dc.journal.fristpage81
dc.journal.lastpage88
dc.identifier.eissn1528-8994
dc.keywordsHeat
dc.keywordsTemperature
dc.keywordsFluids
dc.keywordsThermal energy
dc.keywordsThermal conductivity
dc.keywordsCoal
dc.keywordsEngineering simulation
dc.keywordsFire
dc.keywordsPower stations
dc.keywordsCycles AND Electric power generation
dc.treeJournal of Energy Resources Technology:;2007:;volume( 129 ):;issue: 002