Show simple item record

dc.contributor.authorSayed A. Nassar
dc.contributor.authorPayam H. Matin
dc.date.accessioned2017-05-09T00:21:21Z
dc.date.available2017-05-09T00:21:21Z
dc.date.copyrightAugust, 2006
dc.date.issued2006
dc.identifier.issn0094-9930
dc.identifier.otherJPVTAS-28470#379_1.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/134502
dc.description.abstractThe amount of clamp load due to an externally applied separating force is determined for a boiled assembly in which the fastener is elongated past its proportional limit, while the clamped joint remained within its elastic range. After the initial tightening of the fastener, the joint is subsequently subjected to a tensile separating force, which further increases the fastener tensile stress into the nonlinear range. Such separating force will simultaneously reduce the clamping force in the bolted joint. Upon the removal of the separating service load, the bolted joint system reaches a new equilibrium point between the fastener tension and the joint clamping force. At the new equilibrium point, the fastener tension is reduced from its value at initial assembly, due to the plastic elongation of the fastener. The reduction in fastener tension translates into a partial—yet permanent—loss of the clamping load that may lead to joint leakage, loosening, or fatigue failure. A nonlinear model is established in order to describe the fastener behavior past the proportional limit of its material, and to determine the clamp load loss due to the permanent set in the fastener after the separating force has been removed. Two fastener materials with significantly different rates of strain hardening are used for modeling the behavior of the bolted joint system. The effect of three nondimensional variables on the amount of clamp load loss is investigated. The first variable is the stiffness ratio of the joint and the fastener. The second is the ratio of initial fastener tension to the fastener elastic limit, and the third variable is the ratio of the separating force to the force that causes joint separation to start. Analytical results are presented for a range of stiffness ratios that simulates both soft and hard joint applications. Experimental verification of the analytical results is presented.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleClamp Load Loss due to Fastener Elongation Beyond its Elastic Limit
dc.typeJournal Paper
dc.journal.volume128
dc.journal.issue3
dc.journal.titleJournal of Pressure Vessel Technology
dc.identifier.doi10.1115/1.2217971
dc.journal.fristpage379
dc.journal.lastpage387
dc.identifier.eissn1528-8978
dc.keywordsForce
dc.keywordsStress
dc.keywordsFasteners
dc.keywordsClamps (Tools)
dc.keywordsElongation
dc.keywordsTension AND Stiffness
dc.treeJournal of Pressure Vessel Technology:;2006:;volume( 128 ):;issue: 003
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record