Show simple item record

dc.contributor.authorFabian Mueller
dc.contributor.authorJacob Brouwer
dc.contributor.authorFaryar Jabbari
dc.contributor.authorScott Samuelsen
dc.date.accessioned2017-05-09T00:20:33Z
dc.date.available2017-05-09T00:20:33Z
dc.date.copyrightMay, 2006
dc.date.issued2006
dc.identifier.issn2381-6872
dc.identifier.otherJFCSAU-28925#144_1.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/134071
dc.description.abstractA two-dimensional dynamic model was created for a Siemens Westinghouse type tubular solid oxide fuel cell (SOFC). This SOFC model was integrated with simulation modules for other system components (e.g., reformer, combustion chamber, and dissipater) to comprise a system model that can simulate an integrated 25kw SOFC system located at the University of California, Irvine. A comparison of steady-state model results to data suggests that the integrated model can well predict actual system power performance to within 3%, and temperature to within 5%. In addition, the model predictions well characterize observed voltage and temperature transients that are representative of tubular SOFC system performance. The characteristic voltage transient due to changes in SOFC hydrogen concentration has a time scale that is shown to be on the order of seconds while the characteristic temperature transient is on the order of hours. Voltage transients due to hydrogen concentration change are investigated in detail. Particularly, the results reinforce the importance of maintaining fuel utilization during transient operation. The model is shown to be a useful tool for investigating the impacts of component response characteristics on overall system dynamic performance. Current-based flow control (CBFC), a control strategy of changing the fuel flow rate in proportion to the fuel cell current is tested and shown to be highly effective. The results further demonstrate the impact of fuel flow delay that may result from slow dynamic responses of control valves, and that such flow delays impose major limitations on the system transient response capability.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleDynamic Simulation of an Integrated Solid Oxide Fuel Cell System Including Current-Based Fuel Flow Control
dc.typeJournal Paper
dc.journal.volume3
dc.journal.issue2
dc.journal.titleJournal of Fuel Cell Science and Technology
dc.identifier.doi10.1115/1.2174063
dc.journal.fristpage144
dc.journal.lastpage154
dc.identifier.eissn2381-6910
dc.keywordsFlow (Dynamics)
dc.keywordsTemperature
dc.keywordsFuel cells
dc.keywordsSolid oxide fuel cells
dc.keywordsEquations
dc.keywordsFuels
dc.keywordsSimulation
dc.keywordsHydrogen
dc.keywordsFlow control
dc.keywordsHeat transfer
dc.keywordsCombustion chambers
dc.keywordsStress AND Electric potential
dc.treeJournal of Fuel Cell Science and Technology:;2006:;volume( 003 ):;issue: 002
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)