dc.description.abstractThe parameter identification of a mathematical model of a molten carbonate fuel cell (MCFC) is presented. The model is spatially distributed in two dimensions and describes the strongly non-linear coupling of the temperature field and reactions inside a MCFC. It contains a high number of unknown parameters that need to be validated by experimental means. Therefore, measurements from an industrial 250kW fuel cell power plant are used. This validation approach requires an elaborate strategy, which is presented in detail. The resulting set of parameters can predict the behavior of the MCFC over a broad operating range with a very good precision. The validated model is an important basis for further process optimization and for control system design.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleValidation of a Mathematical Model Using an Industrial MCFC Plant
dc.typeJournal Paper
dc.journal.volume3
dc.journal.issue3
dc.journal.titleJournal of Fuel Cell Science and Technology
dc.identifier.doi10.1115/1.2211634
dc.journal.fristpage303
dc.journal.lastpage307
dc.identifier.eissn2381-6910
dc.keywordsOptimization
dc.keywordsIndustrial plants
dc.keywordsMolten carbonate fuel cells
dc.keywordsMeasurement
dc.keywordsTemperature
dc.keywordsErrors AND Parameter estimation
dc.treeJournal of Fuel Cell Science and Technology:;2006:;volume( 003 ):;issue: 003