Show simple item record

dc.contributor.authorJason J. Cain
dc.contributor.authorYin-Nian Lin
dc.contributor.authorPaul E. Hess
dc.contributor.authorJudy S. Riffle
dc.contributor.authorNathan L. Post
dc.contributor.authorJohn J. Lesko
dc.contributor.authorScott W. Case
dc.date.accessioned2017-05-09T00:20:06Z
dc.date.available2017-05-09T00:20:06Z
dc.date.copyrightJanuary, 2006
dc.date.issued2006
dc.identifier.issn0094-4289
dc.identifier.otherJEMTA8-27078#34_1.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/133816
dc.description.abstractStructural composites are increasingly being utilized in many large naval and civil structures where it is vital that their long-term performance be predictable and their variability definable over the life of the structure. However, these properties may be influenced by the degree of cure of the resin, particularly for room-temperature-cured systems. Thus, this investigation defines the postcure effects on E-glass/vinyl-ester fiber-reinforced polymer (FRP) composites manufactured using the vacuum-assisted resin transfer molding (VARTM) method, which are typical of those used by the US Navy for ship structures. The composites are differentiated by varying levels of postcure temperature and duration, and examined for the effects of advancing cure at various points in the time after postcure. Pseudo-quasi-isotropic [0/+45/90/−45/0]s and angle ply laminate [±45]2s samples from each level of postcure are examined at 1, 10, 30, 100, and 300 days after postcure in order to track strength, stiffness, failure strain, creep, and fatigue performance as functions of time. In parallel, the matrix polymer is inspected using FTIR (Fourier transform infrared spectroscopy) to directly assess the degree of conversion. Dynamic mechanical analysis and shrinkage measurements are also undertaken to assess the Tg and the amount of shrinkage undergone during post-curing, as well as the advancing of the level of cure during the prescribed aging time. Results suggest that the degree of conversion is limited to 80% for the vinyl-ester oligomer and 90–95% for styrene following a postcure of 93°C. It is observed that after 300 days of ambient storage the nonpostcured samples approach the degree of conversion exhibited by those postcured at 93°C, as measured by FTIR. Resin dominated quasi-static properties are greatly affected by the degree of cure, whereas fiber dominated properties are not. Where the degree of cure is comparatively low, viscoelastic properties cause greater changes in creep response as well as influencing fatigue performance.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titlePost-Curing Effects on Marine VARTM FRP Composite Material Properties for Test and Implementation
dc.typeJournal Paper
dc.journal.volume128
dc.journal.issue1
dc.journal.titleJournal of Engineering Materials and Technology
dc.identifier.doi10.1115/1.2128425
dc.journal.fristpage34
dc.journal.lastpage40
dc.identifier.eissn1528-8889
dc.keywordsFatigue
dc.keywordsTemperature
dc.keywordsComposite materials
dc.keywordsLaminates
dc.keywordsFourier transform infrared spectroscopy
dc.keywordsCuring
dc.keywordsEster
dc.keywordsFiber reinforced plastics
dc.keywordsResins
dc.keywordsStorage
dc.keywordsMeasurement
dc.keywordsTesting
dc.keywordsGlass
dc.keywordsCreep AND Stiffness
dc.treeJournal of Engineering Materials and Technology:;2006:;volume( 128 ):;issue: 001
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record