• Login
    View Item 
    •   DSpace Home
    • ASME
    • Journal of Dynamic Systems, Measurement, and Control
    • View Item
    •   DSpace Home
    • ASME
    • Journal of Dynamic Systems, Measurement, and Control
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Torque-Dependent Compliance Control in the Joint Space for Robot-Mediated Motor Therapy

    Thumbnail
    View/Open
    JDSMAA-26351#152_1.pdf (303.2Kb)
    Date
    2006
    Author
    Domenico Formica
    Loredana Zollo
    Eugenio Guglielmelli
    Metadata
    Show full item record
    Abstract
    This paper is focused on the design of interaction control of robotic machines for rehabilitative motor therapy of the upper limb. The control approach tries to address requirements deriving from the application field and adopts a bioinspired approach for regulating robot behavior in the interaction with the patient. An inner-outer loop control scheme is proposed. In order to tune the level of force and improve robot adaptability in the interaction with the patient, a classical outer force control loop is used. For the inner loop, a novel control law for low-level tuning of robot compliance is introduced, that is borrowed from studies on the biological mechanisms for regulating the elastic properties of the human arm. A dedicated simulation tool, which models the dynamics of an operational robotic machine interacting with a human subject, has been developed. Validation of basic adaptability and safety requirements of the control scheme is carried out in simple tasks, e.g., reaching and contact/noncontact transitions, as well as in simulated situations of typical motor exercises. In particular, the simulation tests demonstrate the adaptive capabilities of the proposed control schemes, e.g., in counterbalancing patient incorrect movements related to the various levels of disability. Moreover, preliminar experimental tests carried out on a real robotic system demonstrated the possibility of using the proposed approach for guaranteeing safe interaction with the patient.
    URI
    http://yetl.yabesh.ir/yetl/handle/yetl/133468
    Collections
    • Journal of Dynamic Systems, Measurement, and Control

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV