Evaluation of Aseismic Reliability of Actual Boiler Structures and a Study on Design of Seismic Ties Based on Proof Tests Using a Large Scaled Shaking Table
View/ Open
Date
2004Author
Kiyoshi Aida
Yasuyuki Owa
Kohei Suzuki
Satoshi Fujita
Metadata
Show full item recordAbstract
This paper deals with the evaluation of aseismic reliability of actual boiler plant structures in conjunction with seismic ties, installed between the boiler and the support structures. Proof tests were conducted with a coupled model using a large-scale shake table which verified that the ties acted as energy-absorbing devices against severe earthquakes. Since recent boiler structures are designed based on dynamic response analysis considering the boiler-structure interaction and the effect of energy dissipation of the ties, it is necessary to verify the accuracy of simulation methods. In view of this, the numerical models of the ties are discussed in post analysis. As a result of the post analysis, it is confirmed that (1) seismic ties of existing boiler plants designed by dynamic analysis provide sufficient durability, and (2) the support structures designed by conventional methods have enough aseismic reliability.