dc.description.abstractThe Seismic Design Code for High Pressure Gas Facilities was established in 1982 in advance of those in other industrial fields, the only exception being that for nuclear power plants. In 1995, Hyogoken Nanbu earthquake caused approximately 6000 deaths and more than $1 billion (US) loss of property in the Kobe area, Japan. This unexpected disaster underlined the idea that industrial facilities should pay special consideration to damages including ground failure due to the liquefaction. Strong ground motions caused serious damage to urban structures in the area. Thus, the Seismic Design Code of the High Pressure Gas Facilities were improved to include two-step design assessments, that is, for Level 1 earthquakes (operating basis earthquake: a probable strong earthquake during the service life of the facilities), and Level 2 earthquakes (safety shutdown earthquake: a possible strongest earthquake with extremely low probability of occurrence). For Level 2 earthquakes, ground failure by possible liquefaction will be taken into account. For a Level 1 earthquake, the required seismic performance is that the system must remain safe without critical damage after the earthquake, including no gas leakage. For a Level 2 earthquake, the required seismic performance is that the system must remain safe without gas leakage. This means a certain non-elastic deformation without gas leakage may be allowed. The High Pressure Gas Safety Institute of Japan set up the Seismic Safety Promotion Committee to modify their code, in advance of other industries, and has continued to investigate more effective seismic design practices for more than 5 years. The final version of the guidelines has established design practices for the both Level 1 and Level 2 earthquakes. In this paper, the activities of the committee, their new design concepts and scope of applications are explained.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleDevelopment of Seismic Design Code for High Pressure Gas Facilities in Japan
dc.typeJournal Paper
dc.journal.volume126
dc.journal.issue1
dc.journal.titleJournal of Pressure Vessel Technology
dc.identifier.doi10.1115/1.1638788
dc.journal.fristpage2
dc.journal.lastpage8
dc.identifier.eissn1528-8978
dc.keywordsEarthquake resistant design
dc.keywordsHigh pressure (Physics)
dc.keywordsDesign
dc.keywordsDeformation
dc.keywordsEarthquakes
dc.keywordsPiping systems
dc.keywordsLeakage
dc.keywordsSafety
dc.keywordsFailure
dc.keywordsPipes AND Liquefaction
dc.treeJournal of Pressure Vessel Technology:;2004:;volume( 126 ):;issue: 001