dc.contributor.authorMichael G. Izenson
dc.contributor.authorRoger W. Hill
dc.date.accessioned2017-05-09T00:13:31Z
dc.date.available2017-05-09T00:13:31Z
dc.date.copyrightNovember, 2004
dc.date.issued2004
dc.identifier.issn2381-6872
dc.identifier.otherJFCSAU-27238#10_1.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/130305
dc.description.abstractA key consideration for portable power systems is that they must operate simultaneously at water balance (no external water supply) and thermal balance (controlled temperature). Water and thermal management are intimately linked since evaporation is a potent source of cooling. This paper presents the basic design relationships that govern water and thermal balance in polymer electrolyte membrane (PEM) fuel cell stacks and systems. Hydrogen/air and direct methanol fuel cells are both addressed and compared. Operating conditions for simultaneous water and thermal balance can be specified based on the cell’s electrochemical performance and the operating environment. These conditions can be used to specify the overall size and complexity of the cooling equipment. The water balance properties can have strong effects on the size of the thermal management equipment required.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleWater and Thermal Balance in PEM and Direct Methanol Fuel Cells
dc.typeJournal Paper
dc.journal.volume1
dc.journal.issue1
dc.journal.titleJournal of Fuel Cell Science and Technology
dc.identifier.doi10.1115/1.1782918
dc.journal.fristpage10
dc.journal.lastpage17
dc.identifier.eissn2381-6910
dc.keywordsHeat
dc.keywordsTemperature
dc.keywordsCooling
dc.keywordsFuel cells
dc.keywordsHeat exchangers
dc.keywordsDirect methanol fuel cells
dc.keywordsWater AND Condensers (steam plant)
dc.treeJournal of Fuel Cell Science and Technology:;2004:;volume( 001 ):;issue: 001