Show simple item record

dc.contributor.authorF. L. Eisinger
dc.contributor.authorR. E. Sullivan
dc.contributor.authorP. Feenstra
dc.contributor.authorD. S. Weaver
dc.date.accessioned2017-05-09T00:11:14Z
dc.date.available2017-05-09T00:11:14Z
dc.date.copyrightMay, 2003
dc.date.issued2003
dc.identifier.issn0094-9930
dc.identifier.otherJPVTAS-28425#228_1.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/128995
dc.description.abstractAcoustic vibration in two stack liners located inside a stack downstream of two induced draft fans occurred at high loads. Measurements confirmed that an acoustic wave developed in the fundamental diametral mode of the cylindrical stack liners. It manifested itself as a pure tone traveling through the stack to surrounding residential areas. It was suspected that turbulent flow in the pipe bends upstream of the stack and downstream of the fans was the source of the excitation. Laboratory scale model tests confirmed that the bends indeed acted as the source. Two guide vane configurations placed inside the bends were tested experimentally. The tests showed that properly placed guide vanes would reduce the acoustic levels in the stack. The paper gives a description and evaluation of the problem.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleAcoustic Vibration in a Stack Induced by Pipe Bends
dc.typeJournal Paper
dc.journal.volume125
dc.journal.issue2
dc.journal.titleJournal of Pressure Vessel Technology
dc.identifier.doi10.1115/1.1565080
dc.journal.fristpage228
dc.journal.lastpage232
dc.identifier.eissn1528-8978
dc.keywordsAcoustics
dc.keywordsWaves
dc.keywordsVibration
dc.keywordsPipe bends
dc.keywordsPressure drop
dc.keywordsFlow (Dynamics) AND Sound pressure
dc.treeJournal of Pressure Vessel Technology:;2003:;volume( 125 ):;issue: 002
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record