Show simple item record

dc.contributor.authorP.-S. Lam
dc.contributor.authorY. J. Chao
dc.contributor.authorR. L. Sindelar
dc.contributor.authorX.-K. Zhu
dc.contributor.authorY. Kim
dc.date.accessioned2017-05-09T00:11:12Z
dc.date.available2017-05-09T00:11:12Z
dc.date.copyrightMay, 2003
dc.date.issued2003
dc.identifier.issn0094-9930
dc.identifier.otherJPVTAS-28425#136_1.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/128981
dc.description.abstractMechanical testing of A285 carbon steel, a storage tank material, was performed to develop fracture properties based on the constraint theory of fracture mechanics. A series of single edge-notched bend (SENB) specimen designs with various levels of crack tip constraint were used. The variation of crack tip constraint was achieved by changing the ratio of the initial crack length to the specimen depth. The test data show that the J-R curves are specimen-design-dependent, which is known as the constraint effect. A two-parameter fracture methodology is adopted to construct a constraint-modified J-R curve, which is a function of the constraint parameter, A2, while J remains the loading parameter. This additional fracture parameter is derived from a closed form solution and can be extracted from the finite element analysis for a specific crack configuration. Using this set of SENB test data, a mathematical expression representing a family of the J-R curves for A285 carbon steel can be developed. It is shown that the predicted J-R curves match well with the SENB data over an extensive amount of crack growth. In addition, this expression is used to predict the J-R curve of a compact tension specimen (CT), and reasonable agreement to the actual test data is achieved. To demonstrate its application in a flaw stability evaluation, the configuration of a generic A285 storage tank with a postulated axial flaw is used. For a flaw length of 10% of the tank height, the predicted J-R curve is found to be similar to that for a SENB specimen with a short notch, which is in a state of low constraint. This implies that the use of a J-R curve from the ASTM (American Society for Testing and Materials) standard designs, which typically are high-constraint specimens, may be overly conservative for analysis of fracture resistance of large structures.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleDetermination of Constraint-Modified J-R Curves for Carbon Steel Storage Tanks
dc.typeJournal Paper
dc.journal.volume125
dc.journal.issue2
dc.journal.titleJournal of Pressure Vessel Technology
dc.identifier.doi10.1115/1.1564069
dc.journal.fristpage136
dc.journal.lastpage143
dc.identifier.eissn1528-8978
dc.keywordsCarbon steel
dc.keywordsStress
dc.keywordsFracture (Materials)
dc.keywordsFinite element analysis
dc.keywordsFracture (Process)
dc.keywordsASTM International
dc.keywordsStorage tanks
dc.keywordsElectrical resistance
dc.keywordsEquations AND Design
dc.treeJournal of Pressure Vessel Technology:;2003:;volume( 125 ):;issue: 002
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record