Show simple item record

dc.contributor.authorD. Mukhopadhyay
dc.contributor.authorS. K. Gupta
dc.contributor.authorV. Venkat Raj
dc.date.accessioned2017-05-09T00:08:24Z
dc.date.available2017-05-09T00:08:24Z
dc.date.copyrightNovember, 2002
dc.date.issued2002
dc.identifier.issn0094-9930
dc.identifier.otherJPVTAS-28422#483_1.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/127329
dc.description.abstractECCS is designed to keep the reactor fuel temperatures within safe limits. The paper describes an additional criterion for Indian pressurized heavy water reactors (IPHWRs) evolving from the need to avoid a small break loss of cooling accident (LOCA) developing into a more severe accident. During a small break loss of coolant accident (LOCA) in PHWRs, the hydro-accumulators ride on the system and inject emergency coolant. The atmospheric steam discharge valves (ASDVs) open and cool the system due to energy discharge. In addition, the pressure control system tends to maintain the pressure. Depending on the system design, this could lead to cold pressurization of the system. This paper examines this issue.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleAnalysis of Possibility of Pressure Tube Cold Pressurization During ECCS Injection for a Small Break LOCA
dc.typeJournal Paper
dc.journal.volume124
dc.journal.issue4
dc.journal.titleJournal of Pressure Vessel Technology
dc.identifier.doi10.1115/1.1465438
dc.journal.fristpage483
dc.journal.lastpage486
dc.identifier.eissn1528-8978
dc.keywordsPressure
dc.keywordsHeavy water reactors
dc.keywordsSecondary cells
dc.keywordsTemperature
dc.keywordsCooling
dc.keywordsSteam
dc.keywordsFlow (Dynamics)
dc.keywordsCoolants
dc.keywordsValves
dc.keywordsPressure control AND Nuclear fuels
dc.treeJournal of Pressure Vessel Technology:;2002:;volume( 124 ):;issue: 004
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record