Show simple item record

dc.contributor.authorFrantisek L. Eisinger
dc.contributor.authorRobert E. Sullivan
dc.date.accessioned2017-05-09T00:08:24Z
dc.date.available2017-05-09T00:08:24Z
dc.date.copyrightNovember, 2002
dc.date.issued2002
dc.identifier.issn0094-9930
dc.identifier.otherJPVTAS-28422#418_1.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/127320
dc.description.abstractBurner/furnace systems are generally sensitive to thermoacoustic vibration due to the presence of large temperature differentials between the cold burner air and the hot furnace gases. The systems are predicted to vibrate when the temperature ratio between the hot and cold components reaches a critical value and when the acoustic mode shape of the combined system develops into a Rijke or a Sondhauss tube type. Original full-scale large-utility steam generator systems which vibrated in operation and modified systems resisting the vibration are described and explained. Guidelines for designing systems resistant to thermoacoustic vibration are also given to aid the designers.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleAvoiding Thermoacoustic Vibration in Burner/Furnace Systems
dc.typeJournal Paper
dc.journal.volume124
dc.journal.issue4
dc.journal.titleJournal of Pressure Vessel Technology
dc.identifier.doi10.1115/1.1462623
dc.journal.fristpage418
dc.journal.lastpage424
dc.identifier.eissn1528-8978
dc.keywordsAcoustics
dc.keywordsVibration
dc.keywordsFurnaces
dc.keywordsWaves
dc.keywordsShapes
dc.keywordsOscillations
dc.keywordsGases AND Stability
dc.treeJournal of Pressure Vessel Technology:;2002:;volume( 124 ):;issue: 004