| dc.description.abstract | Reductions in furnace exit gas temperature (FEGT) by changing boiler operating variables and/or adding wall soot blowers and/or lowering burner elevations are investigated. Evaluation of these approaches requires experimental furnace testing and computational furnace modeling. The experimental facility is a Combustion Engineering corner-fired pulverized-coal boiler with a capacity of 606 MWe. Local gas temperature distributions, local radiative and total wall heat flux distributions, and stack NOx were measured during constant-load furnace tests under various combinations of burner configuration, burner tilt angles, excess-O2 setpoints and overfire airflow rate. These measurements are used for tuning and calibrating a furnace model based on the PCGC-3 code developed by Brigham Young University. The experimental data gathered in this work comprise a comprehensive set under controlled conditions on a very-large-scale coal-fired plant and provides information for use in comparing the predictions of furnace-design codes. | |
| dc.publisher | The American Society of Mechanical Engineers (ASME) | |
| dc.title | Local Furnace Data and Modeling Comparison for a 600-MWe Coal-Fired Utility Boiler | |
| dc.type | Journal Paper | |
| dc.journal.volume | 124 | |
| dc.journal.issue | 1 | |
| dc.journal.title | Journal of Energy Resources Technology | |
| dc.identifier.doi | 10.1115/1.1447543 | |
| dc.journal.fristpage | 56 | |
| dc.journal.lastpage | 66 | |
| dc.identifier.eissn | 1528-8994 | |
| dc.keywords | Coal | |
| dc.keywords | Furnaces | |
| dc.keywords | Boilers | |
| dc.keywords | Measurement AND Temperature | |
| dc.tree | Journal of Energy Resources Technology:;2002:;volume( 124 ):;issue: 001 | |
| dc.contenttype | Fulltext | |