Show simple item record

dc.contributor.authorB. G. Shiva Prasad
dc.date.accessioned2017-05-09T00:07:15Z
dc.date.available2017-05-09T00:07:15Z
dc.date.copyrightSeptember, 2002
dc.date.issued2002
dc.identifier.issn0195-0738
dc.identifier.otherJERTD2-26504#187_1.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/126661
dc.description.abstractCompressors are intolerant to liquids. In reciprocating compressors with inherently large volumetric displacement rates, all modes of liquid ingestion pose a serious problem and can even result in catastrophic failures. This paper describes a simple method of estimating the cylinder pressure and “rod load” (force on the crosshead pin, in compressor terminology) in a double-acting reciprocating compressor. The results indicated that even with moderate volume of liquid present inside the cylinder, the pressure could reach values as high as four to five times its normal value with a correspondingly higher rod load.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleEffect of Liquid on a Reciprocating Compressor
dc.typeJournal Paper
dc.journal.volume124
dc.journal.issue3
dc.journal.titleJournal of Energy Resources Technology
dc.identifier.doi10.1115/1.1491981
dc.journal.fristpage187
dc.journal.lastpage190
dc.identifier.eissn1528-8994
dc.keywordsPressure
dc.keywordsCompressors
dc.keywordsCylinders
dc.keywordsStress AND Pistons
dc.treeJournal of Energy Resources Technology:;2002:;volume( 124 ):;issue: 003
dc.contenttypeFulltext