dc.description.abstractWe obtain bounds on achievable sensitivity and complementary sensitivity reduction for a magnetic bearing system in three measurement configurations. We use the sensitivity reduction bounds to deduce achievable robustness and performance limits for each system configuration. We then show how these limits vary with varying magnetic bearing physical dimensions and other parameter values as well as varying closed-loop system bandwidth and controller relative degree. Using all of this information, we derive guidelines for designing magnetic bearing systems and their controllers, for each measurement configuration considered, for greatest achievable robustness and performance.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleMagnetic Bearing Measurement Configurations and Associated Robustness and Performance Limitations
dc.typeJournal Paper
dc.journal.volume124
dc.journal.issue4
dc.journal.titleJournal of Dynamic Systems, Measurement, and Control
dc.identifier.doi10.1115/1.1514671
dc.journal.fristpage589
dc.journal.lastpage598
dc.identifier.eissn1528-9028
dc.keywordsMagnetic bearings AND Robustness
dc.treeJournal of Dynamic Systems, Measurement, and Control:;2002:;volume( 124 ):;issue: 004
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record