Show simple item record

dc.contributor.authorY. Shindo
dc.contributor.authorR. Wang
dc.contributor.authorK. Horiguchi
dc.contributor.authorResearch Associate
dc.date.accessioned2017-05-09T00:05:05Z
dc.date.available2017-05-09T00:05:05Z
dc.date.copyrightJanuary, 2001
dc.date.issued2001
dc.identifier.issn0094-4289
dc.identifier.otherJEMTA8-27017#112_1.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/125344
dc.description.abstractCryogenic interlaminar beam tests in the form of three-point flexure are examined both experimentally and analytically. The use of the short-beam shear test for measuring the interlaminar shear strength of glass-cloth/epoxy laminates at low temperatures is evaluated first. The interlaminar shear tests were carried out with short-beam shear specimens at room temperature, 77 K and 4 K to evaluate the interlaminar shear strength of G-10CR glass-cloth/epoxy laminates. Each specimen was placed on two roller supports that allow lateral motion and a load was applied directly at the center of the specimen. These tests were conducted in accordance with ASTM, 1984, “Standard Test Method for Apparent Interlaminar Shear Strength of Parallel Fiber Composites by Short-Beam Method,” Designation D2344-84. The effects of temperature, specimen width, and span-to-thickness ratio on the apparent interlaminar shear strength are shown graphically. Photomicrographs (scanning electron micrographs, optical micrographs) of actual failure modes were utilized to verify the failure mechanisms. A three-dimensional finite element analysis was also performed to investigate the effects of specimen width and span-to-thickness ratio on the shear stress distribution in the mid-plane. Effective elastic moduli were determined under the assumption of uniform strain inside the representative volume element. The numerical findings are then correlated with the experimental results.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleAnalytical and Experimental Studies of Short-Beam Interlaminar Shear Strength of G-10CR Glass-Cloth/Epoxy Laminates at Cryogenic Temperatures
dc.typeJournal Paper
dc.journal.volume123
dc.journal.issue1
dc.journal.titleJournal of Engineering Materials and Technology
dc.identifier.doi10.1115/1.1286235
dc.journal.fristpage112
dc.journal.lastpage118
dc.identifier.eissn1528-8889
dc.keywordsTemperature
dc.keywordsGlass
dc.keywordsTextiles
dc.keywordsLaminates
dc.keywordsStress
dc.keywordsEpoxy adhesives
dc.keywordsShear (Mechanics)
dc.keywordsFinite element analysis
dc.keywordsFailure
dc.keywordsShear strength
dc.keywordsComposite materials
dc.keywordsThickness
dc.keywordsFibers
dc.keywordsLow temperature
dc.keywordsASTM International
dc.keywordsElasticity AND Elastic moduli
dc.treeJournal of Engineering Materials and Technology:;2001:;volume( 123 ):;issue: 001
dc.contenttypeFulltext