    A Computational Model of a Power Plant Steam Condenser

    Thumbnail
    View/Open
    JERTD2-26494#81_1.pdf (250.8Kb)
    Date
    2001
    Author
    R. P. Roy
    V. K. Gokhale
    M. Ratisher
    Metadata
    Show full item record
    Abstract
    A computational model of a power plant steam condenser which incorporates the effects of air in-leakage and removal on the performance of the condenser is reported. The condenser interior space is modeled as a porous medium. A quasi-three-dimensional approach is taken in which the steady-state steady-flow conservation equations for the steam-air mixture mass, momentum, thermal energy, and air mass fraction are solved for a series of two-dimensional grids perpendicular to the circulating water flow direction. The air removal system is explicitly modeled. The computational model is used to calculate the performance of the steam condenser of a 750-MWe unit at 100 percent load. Some of the calculated variables are compared with measurements obtained in the condenser. The effects of changing various operating parameters on the condenser performance at 100 percent load are also studied.
    URI
    http://yetl.yabesh.ir/yetl/handle/yetl/125120
    Collections
    • Journal of Energy Resources Technology

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV